CARACTERÍSTICAS

Features SPEED7 technology
1 MB work memory
Memory extension (max. 2 MB)
PROFIBUS-DP master / PtP (switchable)
CP 343 integrated
SPEED-Bus -

Technical data power supply

Power supply (rated value) DC 24 V
Power supply (permitted range) DC 20.4...28.8 V
Reverse polarity protection
Current consumption (no-load operation) 270 mA
Current consumption (rated value) 1 A
Inrush current 5 A
I²t 0.5 A²s
Max. current drain at backplane bus 2.5 A
Max. current drain load supply -
Power loss 8.5 W

Load and working memory

Load memory, integrated 2 MB
Load memory, maximum 2 MB
Work memory, integrated 1 MB
Work memory, maximal 2 MB
Memory divided in 50% program / 50% data
Memory card slot MMC-Card with max. 1 GB

Hardware configuration

Racks, max. 4
Modules per rack, max. 8 in multiple-, 32 in a single-rack configuration
Number of integrated DP master 1
Number of DP master via CP 4
Operable function modules 8
Operable communication modules PtP 8
Operable communication modules LAN 8

Command processing times

Bit instructions, min. 0.01 µs
Word instruction, min. 0.01 µs
Double integer arithmetic, min. 0.01 µs
Floating-point arithmetic, min. 0.06 µs

Timers/Counters and their retentive characteristics

Number of S7 counters 512
S7 counter remanence adjustable 0 up to 512
S7 counter remanence adjustable C0 .. C7
Number of S7 times 512
S7 times remanence adjustable 0 up to 512
S7 times remanence adjustable not retentive

Data range and retentive characteristic

Number of flags 8192 Byte
Bit memories retentive characteristic adjustable adjustable 0 up to 8192
Bit memories retentive characteristic preset MB0 .. MB15
Number of data blocks 4095
Max. data blocks size 64 KB
Number range DBs 1 ... 4095
Max. local data size per execution level 510 Byte
Max. local data size per block 510 Byte

Blocks

Number of OBs 24
Maximum OB size 64 KB
Total number DBs, FBs, FCs -
Number of FBs 2048
Maximum FB size 64 KB
Number range FBs 0 ... 2047
Number of FCs 2048
Maximum FC size 64 KB
Number range FCs 0 ... 2047
Maximum nesting depth per priority class 8
Maximum nesting depth additional within an error OB 4

Time

Real-time clock buffered
Clock buffered period (min.) 6 w
Type of buffering Vanadium Rechargeable Lithium Battery
Load time for 50% buffering period 20 h
Load time for 100% buffering period 48 h
Accuracy (max. deviation per day) 10 s
Number of operating hours counter 8
Clock synchronization
Synchronization via MPI Master/Slave
Synchronization via Ethernet (NTP) Slave

Address areas (I/O)

Input I/O address area 8192 Byte
Output I/O address area 8192 Byte
Process image adjustable
Input process image preset 256 Byte
Output process image preset 256 Byte
Input process image maximal 2048 Byte
Output process image maximal 2048 Byte
Digital inputs 65536
Digital outputs 65536
Digital inputs central 1024
Digital outputs central 1024
Integrated digital inputs -
Integrated digital outputs -
Analog inputs 4096
Analog outputs 4096
Analog inputs, central 256
Analog outputs, central 256
Integrated analog inputs -
Integrated analog outputs -

Communication functions

PG/OP channel
Global data communication
Number of GD circuits, max. 8
Size of GD packets, max. 54 Byte
S7 basic communication
S7 basic communication, user data per job 76 Byte
S7 communication
S7 communication as server
S7 communication as client -
S7 communication, user data per job 160 Byte
Number of connections, max. 32

Functionality Sub-D interfaces

Type X2
Type of interface RS485
Connector Sub-D, 9-pin, female
Electrically isolated
MPI
MP²I (MPI/RS232) -
DP master -
DP slave -
Point-to-point interface -
5V DC Power supply max. 90mA, isolated
24V DC Power supply max. 100mA, non-isolated
Type X3
Type of interface RS485
Connector Sub-D, 9-pin, female
Electrically isolated
MPI -
MP²I (MPI/RS232) -
DP master yes
DP slave yes
Point-to-point interface
5V DC Power supply max. 90mA, isolated
24V DC Power supply max. 100mA, non-isolated

Functionality MPI

Number of connections, max. 32
PG/OP channel
Routing
Global data communication
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client -
Transmission speed, min. 19.2 kbit/s
Transmission speed, max. 12 Mbit/s

Functionality PROFIBUS master

PG/OP channel
Routing
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client -
Activation/deactivation of DP slaves
Direct data exchange (slave-to-slave communication) -
DPV1
Transmission speed, min. 9.6 kbit/s
Transmission speed, max. 12 Mbit/s
Number of DP slaves, max. 124
Address range inputs, max. 8 KB
Address range outputs, max. 8 KB
User data inputs per slave, max. 244 Byte
User data outputs per slave, max. 244 Byte

Functionality PROFIBUS slave

PG/OP channel
Routing
S7 communication
S7 communication as server
S7 communication as client -
Direct data exchange (slave-to-slave communication) -
DPV1
Transmission speed, min. 9.6 kbit/s
Transmission speed, max. 12 Mbit/s
Automatic detection of transmission speed -
Transfer memory inputs, max. 244 Byte
Transfer memory outputs, max. 244 Byte
Address areas, max. 32
User data per address area, max. 32 Byte

Point-to-point communication

PtP communication
Interface isolated
RS232 interface -
RS422 interface -
RS485 interface
Connector Sub-D, 9-pin, female
Transmission speed, min. 150 bit/s
Transmission speed, max. 115.5 kbit/s
Cable length, max. 500 m

Point-to-point protocol

ASCII protocol
STX/ETX protocol
3964(R) protocol
RK512 protocol -
USS master protocol
Modbus master protocol
Modbus slave protocol -
Special protocols -

Functionality RJ45 interfaces

Type X5
Type of interface Ethernet 10/100 MBit
Connector RJ45
Electrically isolated
PG/OP channel
Number of connections, max. 4
Productive connections -
Type X8
Type of interface Ethernet 10/100 MBit
Connector RJ45
Electrically isolated
PG/OP channel
Number of connections, max. 32
Productive connections

Ethernet communication CP

Number of productive connections, max. 8
Number of productive connections by Siemens NetPro, max. 8
S7 connections BSEND, BRCV, GET, PUT, Connection of active and passive data handling
User data per S7 connection, max. 32 KB
TCP-connections SEND, RECEIVE, FETCH PASSIV, WRITE PASSIV, Connection of active and passive data handling
User data per TCP connection, max. 64 KB
ISO-connections SEND, RECEIVE, FETCH PASSIV, WRITE PASSIV, Connection of active and passive data handling
User data per ISO connection, max. 8 KB
ISO on TCP connections (RFC 1006) SEND, RECEIVE, FETCH PASSIV, WRITE PASSIV, Connection of active and passive data handling
User data per ISO on TCP connection, max. 32 KB
UDP-connections SEND and RECEIVE
User data per UDP connection, max. 2 KB
UDP-multicast-connections SEND and RECEIVE (max. 8 Multicast groups)
UDP-broadcast-connections SEND

Ethernet open communication

Number of connections, max. 8
User data per ISO on TCP connection, max. 8 KB
User data per native TCP connection, max. 8 KB
User data per ad hoc TCP connection, max. 1460 Byte
User data per UDP connection, max. 1472 Byte

Housing

Material PPE
Mounting Rail System 300

Mechanical data

Dimensions (WxHxD) 80 mm x 125 mm x 120 mm
Weight 430 g

Environmental conditions

Operating temperature 0 °C to 60 °C
Storage temperature -25 °C to 70 °C

Certifications

UL certification yes
KC certification -